产品中心
Home > Products > ESD Protection and Control > CHUERA Intelligent High-Frequency Ionizing Fan

CHUERA Intelligent High-Frequency Ionizing Fan

    CHUERA Intelligent High-Frequency Ionizing Fan

    The CHUERA Intelligent High-Frequency Ionizing Fan is designed for fast static charge neutralization in ESD-sensitive work areas. It combines high-frequency AC ionization, automatic ion needle cleaning, adjustable airflow and wireless communication in a compact enclosure. Real-time equipment monitoring and configurable cleaning functions make it suitable for electronics, precision assembly and other controlled production environments.
  • Share:
  • Contact us Inquiry
  • WhatsApp:8613802573955

Product Overview

The CHUERA Intelligent High-Frequency Ionizing Fan is designed to control static electricity in work areas where electrostatic buildup may affect products, components or manufacturing processes.

The unit generates positive and negative ions through high-frequency AC discharge. These ions help neutralize static charges in the surrounding area, providing continuous support for ESD control during production.

Its integrated display and control functions allow operators to check equipment conditions and adjust operating parameters directly from the front panel.

A-18(2).jpg


High-Frequency Ionization

High-frequency AC discharge technology provides a continuous supply of ions for static charge neutralization.

The ionized airflow helps reduce electrostatic accumulation on products and nearby surfaces, making the equipment suitable for electronics, precision components and other static-sensitive materials.

Under the specified test conditions, the static decay performance can reach within 2 seconds at a 300 mm test distance.

Automatic Ion Needle Cleaning

The ionizing fan includes an automatic cleaning function for the ion-emitting needles.

Users can set the cleaning interval according to the working environment and operating schedule. This reduces the need for frequent manual cleaning and helps keep the ionization components in suitable working condition.

Adjustable Airflow

The fan provides 1–7 levels of airflow adjustment.

Different production areas can require different airflow conditions. Operators can select an appropriate level according to the working distance, product characteristics and surrounding environment.

Real-Time Equipment Monitoring

The large LCD display provides operating information directly on the equipment.

The interface can be used to monitor conditions such as:

  • Fan operating status

  • High-voltage status

  • Ion balance condition

  • Cleaning settings

  • Equipment operating information

This makes routine checks more convenient for operators.

Ion Balance Protection

Stable ion balance is important for effective static elimination.

The system monitors ion balance conditions during operation and can provide an alarm when the measured condition exceeds the configured range. This gives users a direct reference when checking the performance of the ionization system.

Wireless Communication

The product supports wireless communication and can connect with compatible management software.

Through wireless data transmission, equipment information can be collected for remote monitoring and centralized management. This function is useful for production facilities operating multiple ESD control devices.

Password-Based Management

The intelligent control system supports password settings for equipment management.

Access protection can help prevent unintended changes to important operating parameters, which is useful when the equipment is shared by multiple operators.

Maintenance-Friendly Structure

The front fan cover adopts a snap-on design for easier removal and cleaning.

The ion-emitting needle assembly also uses a practical structure that simplifies maintenance. Regular cleaning and inspection can help maintain normal airflow and ionization performance.

Grounding Protection

The unit is designed with grounding protection to improve electrical safety during operation.

Proper grounding and installation should be carried out according to the applicable equipment requirements and workplace electrical safety procedures.

Test Performance

According to the information provided for the product, the static elimination test uses a 300 mm, 600 mm and 900 mm test distance.

The test conditions include humidity of no more than 60%, a test voltage of 1KV–100V and an ambient temperature of 22°C.

At the specified distances, the positive and negative static decay times are approximately:

300 mm: 1.1s positive / 1.3s negative

600 mm: 1.5s positive / 1.7s negative

900 mm: 2.0s positive / 2.3s negative

The specified residual voltage is within ±10V under the stated test conditions. Actual performance may vary with installation distance, airflow, material properties and environmental conditions.

Product Features

  • High-frequency AC ionization

  • Rapid static charge neutralization

  • Automatic ion needle cleaning

  • 1–7 level airflow adjustment

  • Real-time fan status monitoring

  • Ion balance monitoring

  • High-voltage and abnormal-condition alarms

  • Large LCD display

  • Wireless communication capability

  • Password-based equipment management

  • Snap-on front fan cover

  • Convenient maintenance structure

  • Grounding protection

Application Areas

The CHUERA Intelligent High-Frequency Ionizing Fan can be used in production areas where static electricity requires continuous control.

Typical applications include:

  • Electronics assembly

  • Semiconductor handling

  • PCB and SMT production

  • Precision component assembly

  • Optical product manufacturing

  • Laboratory workstations

  • Clean production areas

  • Automated manufacturing equipment

  • Plastic product handling

  • ESD-sensitive inspection areas

Production Line Integration

For production lines with several static-sensitive workstations, the wireless communication function provides an option for connecting individual ionizing fans to a centralized management system.

Operators can use the collected equipment information to understand operating conditions and manage maintenance tasks more efficiently.

Maintenance Considerations

Regular inspection of the fan cover, filter area and ion-emitting components is recommended as part of normal equipment maintenance.

The snap-on fan cover makes cleaning more accessible, while the automatic cleaning function helps reduce the frequency of manual ion needle maintenance.

Actual maintenance intervals should be adjusted according to dust levels, operating hours and the conditions of the production environment.

A-18(1).jpg

FAQ

What is the main function of this ionizing fan?

The main function is to reduce static electricity by generating positive and negative ions that neutralize electrostatic charges in the working area.

What type of ionization technology does it use?

The product uses high-frequency AC ionization technology.

Can the airflow be adjusted?

Yes. The fan provides seven airflow levels, allowing operators to select a suitable setting for different working conditions.

Does the product clean the ion needles automatically?

Yes. An automatic ion needle cleaning function is included, and the cleaning interval can be configured according to operating requirements.

What information can be viewed on the LCD screen?

The display provides equipment operating information such as fan status, high-voltage condition, ion balance and cleaning-related settings.

Does the device support wireless communication?

Yes. Wireless communication is available for transmitting equipment information to compatible management software.

Can operating parameters be protected?

Yes. Password-based management is supported to help control access to equipment settings.

How is the front fan cover maintained?

The front fan cover uses a snap-on structure, allowing it to be removed more easily for cleaning and inspection.

What is the tested static decay time?

Under the stated test conditions, the positive decay time is approximately 1.1s at 300 mm, 1.5s at 600 mm and 2.0s at 900 mm. Negative decay times are approximately 1.3s, 1.7s and 2.3s respectively.

Where can this ionizing fan be used?

It is suitable for electronics, semiconductor, SMT, precision assembly, optical manufacturing, laboratory and other ESD-sensitive working environments.


ONLINE MESSAGE

Please fill in a valid email address
Captcha Can not be empty

RELATED PRODUCTS

Contact Us

Tel:+86-13802573955

Email: electool@chuera.com

Address:No.7-3, Building A, No.1 Tianyang Second Road, Dongfang Community,Songgang Street, Bao'an District, Shenzhen

WhatsApp & WeChat

1.jpg   2.jpg


Copyright © 2026 Shenzhen Chuera Electronics Technology Co., Ltd.   All Rights Reserved.    Support: HZW

Sitemap

This website uses cookies to ensure you get the best experience on our website.

Accept Reject